Transformers, Generators and Motors: Turns Ratio, EMF and Back EMF

Transformers, generators and motors are electromagnetic induction put to work. Generators turn mechanical energy into electrical energy, transformers change the voltage of alternating current so it can be sent across a country with little loss, and motors turn electrical energy back into motion. MDCAT, ECAT, NEET and JEE Main test the turns ratio, efficiency, generator emf and the back emf of motors regularly. This lesson treats each machine in turn and links them through Faraday's and Lenz's laws.

Asked in: MDCAT, NUMS, ECAT, NEET, JEE Main, FSc and Class 11-12 boards

The transformer and the turns ratio

A transformer has two coils, the primary and the secondary, wound on a common soft-iron core. An alternating current in the primary sets up a changing flux in the core, and that same flux links the secondary and induces an emf in it by mutual induction. The emf induced per turn is the same in both coils.

For an ideal transformer (no losses, all flux linked), the voltage ratio equals the turns ratio, and because input power equals output power, the currents are in the inverse ratio. A step-up transformer has more secondary turns: it raises voltage and lowers current. A step-down transformer does the reverse. Power and frequency are not changed.

A transformer does not work on steady DC: a constant current gives a constant flux and therefore no induced emf, and the primary, having low resistance, would draw a large current and overheat.

Efficiency and energy losses

Real transformers are 90% to 99% efficient. Efficiency is output power divided by input power. The lost power appears as heat (and a little sound).

Copper loss is I²R heating in the windings; thick copper wire reduces it. Iron losses occur in the core: eddy currents induced in the core heat it, and are reduced by building the core from thin insulated laminations; hysteresis loss comes from repeatedly magnetising the core, and is reduced by using soft iron (or silicon steel) with a narrow hysteresis loop. Flux leakage, when some primary flux misses the secondary, is reduced by winding one coil over the other.

Humming of a transformer comes from magnetostriction, the tiny change in size of the core each time it is magnetised.

Power transmission

Power stations send power over long lines at very high voltages (for example 132 kV to 500 kV). For a fixed power P, raising the line voltage V lowers the current I = P ÷ V, and the heating loss in the line, I²R, falls as 1 ÷ V².

Step-up transformers at the station raise the voltage for transmission, and a chain of step-down transformers at grid stations and on poles lowers it to 220 V or 230 V for homes. This is the main reason the mains supply is AC, not DC.

The voltage dropped along the line is IR, not the full transmission voltage, so the loss must be found from I²R with the line current, never from V² ÷ R with the supply voltage.

The AC generator

An AC generator (dynamo) has a coil of N turns and area A rotating with angular speed ω in a uniform field B. The flux through it is NBA cos ωt, measured from the position where the plane of the coil is perpendicular to the field.

By Faraday's law the induced emf is ε = NBAω sin ωt, with peak value ε₀ = NBAω. The emf is greatest when the plane of the coil is parallel to the field (flux zero but changing fastest) and zero when the plane is perpendicular to the field (flux greatest but momentarily not changing).

Slip rings and brushes take the alternating emf out to the external circuit. The frequency of the AC equals the number of rotations per second. Doubling the speed of rotation doubles both the peak emf and the frequency.

The DC generator and the DC motor

A DC generator has the same rotating coil but uses a split-ring commutator, which reverses the connections every half turn. The output is a pulsating DC that never changes direction; its average value over a cycle is 2ε₀ ÷ π. Many coils at different angles smooth it out.

A DC motor is the same machine run in reverse: current in the coil in a magnetic field produces a torque, and the commutator reverses the current every half turn to keep the coil turning the same way.

As the motor coil spins in the field, it also acts as a generator. By Lenz's law this induced emf, the back emf εb, opposes the applied voltage. At switch-on the coil is at rest, εb = 0 and the current V ÷ R is very large, so a starter resistance is used. As speed rises, εb rises and the current falls. If the load increases, the motor slows, εb falls and it draws more current; a jammed motor can burn out.

Electrical input VI is split into mechanical power εbI and heat I²R. The efficiency is εb ÷ V. The mechanical power is greatest when εb = V ÷ 2, where the efficiency is 50%.

Eddy currents

When a solid conductor moves in a magnetic field, or sits in a changing field, circulating currents called eddy (Foucault) currents are induced in its body. By Lenz's law they oppose the motion or the change that produced them, and they heat the conductor.

Unwanted eddy currents waste energy in transformer and motor cores; laminating the core breaks up their paths and greatly reduces them. A metal plate with slots cut in it swings much more freely through a magnet than a solid plate, for the same reason.

Useful applications include electromagnetic damping of moving-coil galvanometers (dead-beat movement), magnetic braking of trains, induction furnaces that melt metals, induction cooktops, energy meters and car speedometers.

Solved examples

  1. Ravi's ideal transformer has 200 primary turns and 3000 secondary turns. The primary is connected to a 230 V supply and the secondary delivers 0.1 A. Find the secondary voltage and the primary current.
    1. Vs = Vp × Ns ÷ Np = 230 × 3000 ÷ 200 = 3450 V. It is a step-up transformer.
    2. For an ideal transformer, Ip = Is × Ns ÷ Np = 0.1 × 15 = 1.5 A.
    3. Check: input power 230 × 1.5 = 345 W equals output 3450 × 0.1 = 345 W.
    Answer: Vs = 3450 V; Ip = 1.5 A
  2. A step-down transformer is 90% efficient. It is fed from 220 V and supplies 9 A at 22 V to a load. Find the input power, the primary current and the power lost.
    1. Output power = 22 × 9 = 198 W.
    2. Input power = 198 ÷ 0.90 = 220 W.
    3. Primary current = 220 ÷ 220 = 1.0 A (an ideal transformer would need only 0.9 A).
    4. Power lost = 220 − 198 = 22 W, mostly as copper and core heating.
    Answer: P(in) = 220 W, Ip = 1.0 A, loss = 22 W
  3. A plant sends 100 kW to a village through lines of total resistance 5 Ω. Compare the line loss when the power is transmitted at 2 kV and at 20 kV.
    1. At 2 kV: I = 100 000 ÷ 2000 = 50 A; loss = 50² × 5 = 12 500 W, that is 12.5% of the power.
    2. At 20 kV: I = 100 000 ÷ 20 000 = 5 A; loss = 5² × 5 = 125 W, only 0.125%.
    3. Ten times the voltage gives one hundredth of the loss, as P²R ÷ V² predicts.
    Answer: 12.5 kW at 2 kV versus 125 W at 20 kV
  4. An AC generator has a coil of 100 turns, each of area 0.05 m², rotating at 50 revolutions per second in a field of 0.2 T. Find the peak and rms emf.
    1. ω = 2π × 50 ≈ 314 rad/s.
    2. ε₀ = NBAω = 100 × 0.2 × 0.05 × 314 ≈ 314 V.
    3. ε(rms) = 314 ÷ √2 ≈ 222 V.
    4. The output frequency is 50 Hz, the same as the rotation rate.
    Answer: Peak ≈ 314 V; rms ≈ 222 V
  5. Priya's DC motor runs on 220 V. Its armature resistance is 2 Ω and it draws 10 A at full speed. Find the back emf, the mechanical power, the efficiency and the current at the instant of switching on.
    1. Back emf εb = V − IR = 220 − 10 × 2 = 200 V.
    2. Mechanical power = εb I = 200 × 10 = 2000 W; input = 220 × 10 = 2200 W.
    3. Efficiency = 200 ÷ 220 ≈ 90.9%.
    4. At switch-on εb = 0, so I = 220 ÷ 2 = 110 A, eleven times the running current. This is why a starter resistance is used.
    Answer: εb = 200 V, 2000 W, about 90.9%, starting current 110 A
  6. A small DC motor with armature resistance 3 Ω runs on a 12 V supply. Find the largest mechanical power it can deliver and the current and efficiency at that point.
    1. Mechanical power P = εb I = (V − IR) I, which is greatest when εb = V ÷ 2 = 6 V.
    2. Then I = (12 − 6) ÷ 3 = 2 A.
    3. P(max) = 6 × 2 = 12 W, which equals V² ÷ (4R) = 144 ÷ 12.
    4. Efficiency = εb ÷ V = 50%; the other 12 W heats the armature.
    Answer: 12 W at 2 A, with 50% efficiency

Exam shortcuts

Common mistakes

Practice MCQs

  1. A transformer works on the principle of:
    A) self-induction
    B) mutual induction
    C) electrostatic induction
    D) magnetic force on a current
    Answer: B) mutual induction — A changing current in the primary changes the flux linking the secondary, inducing an emf there: mutual induction. Self-induction concerns one coil alone, electrostatic induction involves charges not flux, and the force on a current is the motor principle.
  2. The core of a transformer is laminated mainly to reduce:
    A) hysteresis loss
    B) copper loss
    C) flux leakage
    D) eddy current loss
    Answer: D) eddy current loss — Thin insulated sheets break the paths of eddy currents in the core. Hysteresis loss is reduced by choosing soft iron, copper loss by thick windings, and flux leakage by winding the coils on top of each other.
  3. In an ideal step-up transformer, which quantity in the secondary is smaller than in the primary?
    A) the frequency
    B) the power
    C) the current
    D) the emf induced per turn
    Answer: C) the current — Voltage rises in proportion to the turns, so the current falls in the same proportion to keep power constant. Frequency and power are unchanged, and the emf per turn is the same in both coils because they share the same changing flux.
  4. An ideal transformer has 500 primary turns and 50 secondary turns. When the secondary supplies 2 A, the primary current is:
    A) 0.2 A
    B) 20 A
    C) 2 A
    D) 0.02 A
    Answer: A) 0.2 A — Ip = Is × Ns ÷ Np = 2 × 50 ÷ 500 = 0.2 A. 20 A inverts the turns ratio, 2 A ignores the ratio, and 0.02 A applies the ratio twice.
  5. Eddy currents are put to good use in:
    A) a fuse wire
    B) a filament lamp
    C) induction cooktops
    D) a dry cell
    Answer: C) induction cooktops — An induction cooktop uses a rapidly changing field to induce eddy currents in the metal pan, heating it directly. A fuse wire and a lamp filament are heated by ordinary conduction current, and a dry cell produces emf chemically.
  6. The emf of a simple AC generator is greatest at the instant when the plane of its coil is:
    A) perpendicular to the magnetic field
    B) parallel to the magnetic field
    C) at 45° to the magnetic field
    D) at any angle, since the emf is constant
    Answer: B) parallel to the magnetic field — When the plane is parallel to B, the flux is zero but changing fastest, so ε = NBAω sin ωt is at its peak. When the plane is perpendicular, the flux is greatest and momentarily constant, so the emf is zero; at 45° it is 0.707 of the peak, and the emf is alternating, not constant.
  7. A generator coil of 50 turns, area 0.04 m², rotates at 100 rad/s in a field of 0.5 T. Its peak emf is:
    A) 100 V
    B) 70.7 V
    C) 628 V
    D) 2.0 V
    Answer: A) 100 V — ε₀ = NBAω = 50 × 0.5 × 0.04 × 100 = 100 V. 70.7 V is the rms value, 628 V treats 100 as revolutions per second and multiplies by 2π, and 2.0 V leaves out the number of turns.
  8. At the instant a DC motor is switched on, its back emf is:
    A) zero
    B) maximum
    C) equal to the supply voltage
    D) half the supply voltage
    Answer: A) zero — Back emf is proportional to the speed of the coil, which is zero at start, so the current V ÷ R is at its largest. It rises towards the supply voltage only as the motor speeds up; half the supply voltage is the condition for maximum mechanical power.
  9. A transformer of efficiency 95% takes 5 A from a 220 V supply and gives an output at 11 V. The secondary current is:
    A) 100 A
    B) 105 A
    C) 0.25 A
    D) 95 A
    Answer: D) 95 A — Output power = 0.95 × 220 × 5 = 1045 W, so Is = 1045 ÷ 11 = 95 A. 100 A assumes an ideal transformer, 105 A divides by the efficiency instead of multiplying, and 0.25 A inverts the voltage ratio.
  10. For the same power sent through the same line, the transmission voltage is raised 10 times. The power lost as heat in the line becomes:
    A) 1/10 of its earlier value
    B) 1/100 of its earlier value
    C) 10 times its earlier value
    D) 1/1000 of its earlier value
    Answer: B) 1/100 of its earlier value — The line current falls to 1/10, and the loss I²R falls to 1/100. 1/10 forgets to square the current, 10 times wrongly uses V² ÷ R with the supply voltage, and 1/1000 cubes the factor.
  11. A DC motor connected to 240 V has an armature resistance of 4 Ω and draws 5 A while running. Its efficiency (ignoring friction) is about:
    A) 8.3%
    B) 100%
    C) 91.7%
    D) 83.3%
    Answer: C) 91.7% — Back emf = 240 − 5 × 4 = 220 V, and efficiency = εb ÷ V = 220 ÷ 240 ≈ 91.7%. 8.3% is the fraction lost as heat, 100% ignores the armature resistance, and 83.3% wrongly subtracts 40 V.
  12. A 220 V DC motor has an armature resistance of 1 Ω and draws 10 A at its normal speed. The ratio of the starting current to the running current is:
    A) 21
    B) 1.05
    C) 10
    D) 22
    Answer: D) 22 — Starting current (εb = 0) = 220 ÷ 1 = 220 A, and 220 ÷ 10 = 22. 21 is the back emf (210 V) divided by the running current, 1.05 is 220 ÷ 210, and 10 is just the running current.
  13. The speed of rotation of an AC generator coil is doubled, with everything else unchanged. Then:
    A) both peak emf and frequency double
    B) peak emf doubles, frequency unchanged
    C) frequency doubles, peak emf unchanged
    D) both stay the same
    Answer: A) both peak emf and frequency double — ε₀ = NBAω and f = ω ÷ (2π), so both are proportional to the speed and both double. The other choices keep one of them fixed, which would contradict these formulas.
  14. A generator has a peak emf of 200 V. Its emf at the instant when the normal to the coil makes 30° with the magnetic field is:
    A) 173 V
    B) 200 V
    C) 100 V
    D) zero
    Answer: C) 100 V — With θ measured between the normal and B, ε = ε₀ sin θ = 200 × 0.5 = 100 V. 173 V uses cos 30°, which would apply if 30° were the angle between the plane and B; 200 V and zero are the values with the plane parallel and perpendicular to B.
  15. A DC motor has an armature resistance of 2 Ω and runs on a 24 V supply. The largest mechanical power it can deliver is:
    A) 288 W
    B) 72 W
    C) 144 W
    D) 36 W
    Answer: B) 72 W — Maximum mechanical power is V² ÷ (4R) = 576 ÷ 8 = 72 W, reached when εb = 12 V and I = 6 A. 288 W is V² ÷ R, the power at stall, all wasted as heat; 144 W is the total input at that point; 36 W halves the correct value.

Questions

Why does a transformer get hot even with no load?

With the secondary open, the primary still draws a small magnetising current. The alternating flux causes hysteresis and eddy current losses in the core, so some power is always used even without a load.

Why does a motor draw more current when it is loaded?

A load slows the motor, which reduces the back emf. Since I = (V − εb) ÷ R, a smaller back emf means a larger current, which supplies the extra mechanical power needed.

What is the difference between an AC and a DC generator?

Both have a coil rotating in a field. The AC generator uses two slip rings, so the output alternates. The DC generator uses a split-ring commutator that reverses the connections every half turn, so the output is in one direction, though it pulsates.

Can a transformer change the frequency of AC?

No. The secondary emf is induced by the same changing flux as the primary, so it has exactly the same frequency. Only the voltage and current levels change.