Thermodynamic Processes: Work, P-V Cycles, Carnot and COP Numericals
Once the first law and the four standard processes are known, entry-test questions become calculations: the work in an isothermal expansion, the final temperature after an adiabatic compression, the net work of a cycle from its P-V diagram, or the coefficient of performance of a refrigerator. This lesson collects the formula for each process in one place and drills the numericals that MDCAT, ECAT, NEET and JEE Main set, with the ln and power values stated so that no calculator is needed.
Asked in: MDCAT, NUMS, ECAT, NEET, JEE Main, FSc and Class 11-12 boards
First law, sign convention and P-V work
The first law is Q = ΔU + W, where Q is the heat given to the gas, ΔU the rise in its internal energy and W the work done by the gas. Heat absorbed and work done by the gas are positive; heat rejected and work done on the gas are negative.
The work done by a gas is the area under its path on a P-V diagram: positive for expansion, negative for compression. Different paths between the same two states enclose different areas, so W and Q depend on the path, while ΔU = nCᵥΔT depends only on the end temperatures. This is true for any process of an ideal gas, not only at constant volume.
- Q = ΔU + W
- W = area under the P-V curve
- ΔU = nCᵥΔT (any process, ideal gas)
Isobaric and isochoric processes
At constant pressure, W = PΔV = nRΔT and the heat supplied is Q = nCₚΔT. Only part of the heat goes into work: the fraction W ÷ Q = R ÷ Cₚ, which is 2/5 for a monatomic gas and 2/7 for a diatomic gas. The rest raises the internal energy.
At constant volume the gas does no work, so all the heat changes the internal energy: Q = ΔU = nCᵥΔT. For an ideal monatomic gas Cᵥ = 3R/2 and Cₚ = 5R/2; for a diatomic gas Cᵥ = 5R/2 and Cₚ = 7R/2.
- Isobaric: W = PΔV = nRΔT; Q = nCₚΔT
- Isochoric: W = 0; Q = ΔU = nCᵥΔT
- Cₚ − Cᵥ = R
Isothermal processes
At constant temperature, the internal energy of an ideal gas does not change, so all the heat absorbed is converted into work: Q = W. The gas obeys PV = constant, and its curve on a P-V graph is a rectangular hyperbola.
The work is W = nRT ln(V₂ ÷ V₁) = nRT ln(P₁ ÷ P₂). In terms of common logarithms, ln x = 2.303 log x. Useful values: ln 2 = 0.693, ln 3 = 1.099, ln 4 = 1.386, ln 10 = 2.303. In an isothermal compression W is negative and the same amount of heat is given out.
- W = nRT ln(V₂ ÷ V₁) = 2.303 nRT log(V₂ ÷ V₁)
- ΔU = 0, Q = W
Adiabatic processes
In an adiabatic process no heat enters or leaves (Q = 0), so W = −ΔU: a gas that expands adiabatically cools, and one that is compressed adiabatically heats up. The gas obeys PVᵞ = constant, TVᵞ⁻¹ = constant, where γ = Cₚ ÷ Cᵥ (5/3 for monatomic and 7/5 for diatomic gases).
The work done by the gas is W = (P₁V₁ − P₂V₂) ÷ (γ − 1) = nR(T₁ − T₂) ÷ (γ − 1) = nCᵥ(T₁ − T₂). At any point the slope of an adiabatic curve is γ times the slope of the isothermal curve through that point, so adiabats are steeper.
- PVᵞ = constant; TVᵞ⁻¹ = constant
- W = nR(T₁ − T₂) ÷ (γ − 1) = nCᵥ(T₁ − T₂)
- Slope of adiabat = γ × slope of isotherm
Cyclic processes on a P-V diagram
In a cycle the gas returns to its starting state, so ΔU = 0 for the whole cycle and the net heat absorbed equals the net work done. The net work equals the area enclosed by the loop.
If the loop is traced clockwise on a P-V diagram, the net work is done by the gas (an engine); if anticlockwise, net work is done on the gas (a refrigerator). For a rectangle the area is ΔP × ΔV; for a triangle it is ½ × ΔP × ΔV. To find the heat in one unknown step, add up the heat and work of the other steps and use net Q = net W.
- Cycle: ΔU = 0, net Q = net W = enclosed area
- Clockwise: positive net work (engine)
Carnot engine, refrigerator and heat pump
A Carnot engine works between a hot reservoir at T₁ and a cold one at T₂ (kelvin) and has the greatest possible efficiency η = 1 − T₂ ÷ T₁ = W ÷ Q₁. For a Carnot cycle Q₂ ÷ Q₁ = T₂ ÷ T₁.
Run backwards, it becomes a refrigerator that takes heat Q₂ from the cold space using work W. Its coefficient of performance is COP = Q₂ ÷ W = T₂ ÷ (T₁ − T₂). A heat pump that warms a room delivers Q₁, so its COP = Q₁ ÷ W = T₁ ÷ (T₁ − T₂). For the same reservoirs, COP(refrigerator) = (1 − η) ÷ η. When two engines are run in series, equal efficiencies need an intermediate temperature √(T₁T₂), while equal work outputs need (T₁ + T₂) ÷ 2.
- η = 1 − T₂ ÷ T₁ = W ÷ Q₁
- COP(refrigerator) = Q₂ ÷ W = T₂ ÷ (T₁ − T₂) = (1 − η) ÷ η
- COP(heat pump) = T₁ ÷ (T₁ − T₂)
Solved examples
- Two moles of an ideal diatomic gas are heated at constant pressure from 300 K to 400 K. Find the work done, the heat supplied and the rise in internal energy (R = 8.31 J/(mol·K)).
- W = nRΔT = 2 × 8.31 × 100 = 1662 J.
- Cₚ = 7R/2 for a diatomic gas, so Q = nCₚΔT = 2 × 3.5 × 8.31 × 100 = 5817 J.
- ΔU = Q − W = 5817 − 1662 = 4155 J (check: nCᵥΔT = 2 × 2.5 × 8.31 × 100 = 4155 J).
Answer: W = 1662 J, Q = 5817 J, ΔU = 4155 J - One mole of an ideal gas at 300 K is compressed isothermally from 10 L to 2.5 L. Find the work done and the heat exchanged (R = 8.31 J/(mol·K), ln 4 = 1.386).
- W = nRT ln(V₂ ÷ V₁) = 8.31 × 300 × ln(2.5 ÷ 10) = −8.31 × 300 × ln 4.
- W = −8.31 × 300 × 1.386 ≈ −3455 J, so about 3455 J of work is done on the gas.
- ΔU = 0, so Q = W = −3455 J: the gas gives out about 3455 J of heat.
Answer: About 3.46 kJ of work is done on the gas, and the same amount of heat is released - One mole of a monatomic ideal gas (γ = 5/3) at 300 K is compressed adiabatically to one-eighth of its volume. Find the final temperature, the pressure ratio and the work done on the gas (R = 8.31 J/(mol·K); 8 raised to 2/3 = 4, 8 raised to 5/3 = 32).
- TVᵞ⁻¹ is constant, so T₂ = T₁ × 8 raised to (γ − 1) = 300 × 8 raised to 2/3 = 300 × 4 = 1200 K.
- PVᵞ is constant, so P₂ ÷ P₁ = 8 raised to 5/3 = 32.
- Work done by the gas = nR(T₁ − T₂) ÷ (γ − 1) = 8.31 × (300 − 1200) ÷ (2/3) ≈ −11 218 J.
- So about 11.2 kJ of work is done on the gas, all of which raises its internal energy.
Answer: 1200 K; pressure rises 32 times; about 11.2 kJ of work done on the gas - Ali takes a gas round a rectangular cycle on a P-V diagram, clockwise, between pressures 1 × 10⁵ Pa and 3 × 10⁵ Pa and volumes 1 × 10⁻³ m³ and 4 × 10⁻³ m³. Find the net work done and the net heat absorbed per cycle.
- Enclosed area = ΔP × ΔV = (3 − 1) × 10⁵ × (4 − 1) × 10⁻³ = 600 J.
- The cycle is clockwise, so the gas does +600 J of net work.
- ΔU = 0 over a cycle, so the net heat absorbed = 600 J.
Answer: 600 J of work by the gas and 600 J of net heat absorbed - A Carnot engine works between 500 K and 300 K and delivers 800 J of work per cycle. Find its efficiency, the heat absorbed and the heat rejected per cycle.
- η = 1 − 300 ÷ 500 = 0.4, that is 40%.
- Q₁ = W ÷ η = 800 ÷ 0.4 = 2000 J.
- Q₂ = Q₁ − W = 2000 − 800 = 1200 J (check: Q₂ ÷ Q₁ = 300 ÷ 500 = 0.6).
Answer: 40%; 2000 J absorbed; 1200 J rejected - An ideal (Carnot) freezer keeps its inside at −13 °C in a room at 27 °C. Find its COP, the work needed to remove 13 000 J of heat from the inside, and the heat given to the room.
- T₂ = 260 K and T₁ = 300 K, so COP = 260 ÷ (300 − 260) = 6.5.
- Work = Q₂ ÷ COP = 13 000 ÷ 6.5 = 2000 J.
- Heat given to the room = Q₂ + W = 13 000 + 2000 = 15 000 J.
Answer: COP = 6.5; 2000 J of work; 15 000 J to the room
Exam shortcuts
- Name the zero first: isothermal ΔU = 0, adiabatic Q = 0, isochoric W = 0, cycle ΔU = 0.
- ΔU = nCᵥΔT holds in every process of an ideal gas, so use it even when the volume changes.
- Cycle questions: net work = enclosed area, clockwise positive; then use net Q = net W for any missing heat.
- Change every Celsius temperature to kelvin before using Carnot or COP formulas.
- COP of a refrigerator = (1 − η) ÷ η for the same reservoirs; η = 20% gives COP = 4.
Common mistakes
- Using nRT ln(V₂ ÷ V₁) for an adiabatic process; that formula is only for isothermal changes.
- Writing Q = nCᵥΔT for an isobaric process; at constant pressure use Cₚ.
- Using the heat pump formula T₁ ÷ (T₁ − T₂) for a refrigerator, or the other way round.
- Forgetting that the work in a cycle has a sign: an anticlockwise loop means work is done on the gas.
Practice MCQs
- The work done by an ideal gas when it is heated at constant volume is:
A) PΔV
B) nRΔT
C) nCᵥΔT
D) Zero
Answer: D) Zero — With no change in volume there is no area under the P-V path, so W = 0. PΔV and nRΔT are the isobaric work, and nCᵥΔT is the heat supplied, which all goes into internal energy here. - When an ideal gas expands isothermally, the heat it absorbs is equal to:
A) The increase in its internal energy
B) The work done by the gas
C) Zero
D) Half the work done by the gas
Answer: B) The work done by the gas — At constant temperature ΔU = 0, so Q = W: all the heat goes into the work of expansion. The internal energy does not rise, heat is certainly absorbed during expansion, and no factor of one half appears. - Three moles of an ideal gas are heated at constant pressure through 50 K. The work done by the gas is (R = 8.3 J/(mol·K)):
A) 1245 J
B) 1867.5 J
C) 3112.5 J
D) 415 J
Answer: A) 1245 J — W = nRΔT = 3 × 8.3 × 50 = 1245 J. 1867.5 J is the rise in internal energy of a monatomic gas, 3112.5 J is the heat supplied to a monatomic gas, and 415 J leaves out the number of moles. - A gas is taken round a triangular cycle on a P-V diagram whose base spans 4 × 10⁻³ m³ of volume and whose height spans 2 × 10⁵ Pa of pressure. The magnitude of the net work per cycle is:
A) 800 J
B) 200 J
C) 400 J
D) 0 J
Answer: C) 400 J — Net work = enclosed area = ½ × 4 × 10⁻³ × 2 × 10⁵ = 400 J. 800 J treats the triangle as a rectangle, 200 J halves twice, and zero would be true only for ΔU over a cycle, not the work. - Two moles of an ideal gas at 400 K expand isothermally from 5 L to 10 L. The work done by the gas is (R = 8.31 J/(mol·K), ln 2 = 0.693):
A) About 2.30 kJ
B) About 4.61 kJ
C) About 10.6 kJ
D) Zero, since the temperature is constant
Answer: B) About 4.61 kJ — W = nRT ln 2 = 2 × 8.31 × 400 × 0.693 ≈ 4607 J ≈ 4.61 kJ. 2.30 kJ uses one mole, 10.6 kJ multiplies by 2.303 a second time, and constant temperature makes ΔU zero, not the work. - At a given point on a P-V diagram, the slope of the adiabatic curve divided by the slope of the isothermal curve through that point equals:
A) 1
B) 1 ÷ γ
C) γ − 1
D) γ
Answer: D) γ — For an isotherm dP/dV = −P/V, and for an adiabat dP/dV = −γP/V, so the ratio is γ and the adiabat is steeper. A ratio of 1 would make them identical, while 1 ÷ γ and γ − 1 come from slips in differentiating PVᵞ. - An ideal diatomic gas (γ = 1.4) at 300 K is compressed adiabatically to half its volume. Taking 2 raised to 0.4 = 1.32, its final temperature is about:
A) 396 K
B) 227 K
C) 600 K
D) 300 K
Answer: A) 396 K — T₂ = T₁ × 2 raised to (γ − 1) = 300 × 1.32 ≈ 396 K. 227 K divides instead of multiplying (that would be an expansion), 600 K uses the isobaric or Charles-law idea, and 300 K treats the process as isothermal. - Two moles of a monatomic ideal gas expand adiabatically and cool from 500 K to 350 K. The work done by the gas is (R = 8.31 J/(mol·K)):
A) 2493 J
B) 6233 J
C) 3740 J
D) 1870 J
Answer: C) 3740 J — W = nCᵥ(T₁ − T₂) = 2 × 1.5 × 8.31 × 150 ≈ 3740 J. 2493 J uses nRΔT, 6233 J uses Cₚ instead of Cᵥ, and 1870 J is the value for only one mole. - A monatomic ideal gas is heated at constant pressure. The fraction of the heat supplied that is converted into work is:
A) 2/5
B) 3/5
C) 2/3
D) 1
Answer: A) 2/5 — W ÷ Q = nRΔT ÷ nCₚΔT = R ÷ (5R/2) = 2/5. 3/5 is the fraction that goes into internal energy, 2/3 is γ − 1 for this gas, and 1 is true only for an isothermal process. - A Carnot engine has an efficiency of 25% when its sink is at 27 °C. The temperature of its source is:
A) 400 °C
B) 127 °C
C) 102 °C
D) 36 °C
Answer: B) 127 °C — T₁ = T₂ ÷ (1 − η) = 300 ÷ 0.75 = 400 K = 127 °C. 400 °C forgets to convert back from kelvin, 102 °C multiplies 300 by 1.25, and 36 °C uses 27 °C directly without converting to kelvin. - An ideal refrigerator keeps its inside at 0 °C while the room is at 27 °C. Its coefficient of performance is about:
A) 11.1
B) 0.09
C) 1.1
D) 10.1
Answer: D) 10.1 — COP = T₂ ÷ (T₁ − T₂) = 273 ÷ 27 ≈ 10.1. 11.1 uses the heat pump form 300 ÷ 27, 0.09 is the Carnot efficiency 27 ÷ 300, and 1.1 is just 300 ÷ 273. - An ideal heat pump keeps a house at 27 °C when the outside air is at 7 °C. The heat delivered to the house per joule of work is:
A) 14 J
B) 0.067 J
C) 15 J
D) 1.07 J
Answer: C) 15 J — COP(heat pump) = T₁ ÷ (T₁ − T₂) = 300 ÷ 20 = 15, so 15 J is delivered per joule. 14 is the refrigerator COP 280 ÷ 20, 0.067 is the efficiency 20 ÷ 300, and 1.07 is 300 ÷ 280. - A Carnot engine has an efficiency of 1/5. If it is run in reverse as a refrigerator between the same reservoirs, its coefficient of performance is:
A) 4
B) 5
C) 0.25
D) 6
Answer: A) 4 — COP = (1 − η) ÷ η = (4/5) ÷ (1/5) = 4. 5 is 1 ÷ η, which is the heat pump COP, 0.25 inverts the correct answer, and 6 adds η instead of subtracting it. - A gas goes round a cycle A to B to C to A. From A to B (constant volume) it absorbs 600 J. From B to C (isothermal expansion) it absorbs 400 J. From C to A (constant pressure compression) 250 J of work is done on it. The heat rejected from C to A is:
A) 600 J
B) 250 J
C) 850 J
D) 1150 J
Answer: C) 850 J — Net work = 0 + 400 − 250 = 150 J, and over a cycle net Q = net W, so Q(CA) = 150 − (600 + 400) = −850 J: 850 J is rejected. 600 J is only the fall in internal energy, 250 J is the work on the gas, and 1150 J adds the net work instead of subtracting it. - Two Carnot engines work in series: the first takes heat at 800 K and rejects it at temperature T to the second, which rejects heat at 200 K. If both engines have the same efficiency, T is:
A) 500 K
B) 400 K
C) 300 K
D) 160 K
Answer: B) 400 K — Equal efficiency means T ÷ 800 = 200 ÷ T, so T = √(800 × 200) = 400 K. 500 K is the arithmetic mean, which gives equal work instead, 300 K has no basis, and 160 K is the product divided by the sum.
Questions
Why is the work done different along different paths between the same two states?
Work is the area under the path on a P-V diagram, and different paths enclose different areas. Internal energy depends only on the state (temperature for an ideal gas), so ΔU is the same for every path, and Q adjusts to keep Q = ΔU + W.
Why does a gas cool when it expands adiabatically?
It does work pushing back its surroundings, but no heat flows in to replace the energy. The work must come from its internal energy, so the molecules slow down and the temperature falls.
Can a refrigerator have a COP greater than 1?
Yes, and it usually does. COP compares the heat removed with the work put in, and moving heat is easier than creating it. A small temperature difference between inside and outside gives a large COP.
Why must the Carnot formulas use kelvin?
The ratio T₂ ÷ T₁ comes from the ideal gas law, which uses absolute temperature. Celsius values are shifted by 273 and give wrong ratios; 27 °C ÷ 127 °C is not equal to 300 K ÷ 400 K.